| 8 | 1/1 | 返回列表 |
| 查看: 1361 | 回復(fù): 7 | |||
liufangfw金蟲 (小有名氣)
|
[交流]
幫忙查是否被EI收錄
|
|
幫忙查一篇論文是否被EI收錄,謝謝! 循環(huán)冷卻水系統(tǒng)操作條件對其中生物黏泥成分及性能的影響,石油學(xué)報(石油加工),2010年,26(3):456-461。 |
至尊木蟲 (文壇精英)
鐵桿木蟲 (知名作家)

鐵桿木蟲 (正式寫手)
木蟲 (職業(yè)作家)
至尊木蟲 (著名寫手)
|
Effects of operating conditions on biofouling components and characteristics in circulation cooling water system Liu, Fang (College of Chemistry and Chemical Engineering, China University of Petroleum, Qingdao 266555, China); Zhang, Guizhi; Zhao, Chaocheng; Xia, Lu; Zhang, Pei Source: Shiyou Xuebao, Shiyou Jiagong/Acta Petrolei Sinica (Petroleum Processing Section), v 26, n 3, p 456-461, June 2010 Language: Chinese Database: Compendex |

至尊木蟲 (著名寫手)
|
Accession number: 20102813077103 Title: Effects of operating conditions on biofouling components and characteristics in circulation cooling water system Authors: Liu, Fang1 ; Zhang, Guizhi1 ; Zhao, Chaocheng1 ; Xia, Lu1 ; Zhang, Pei1 Author affiliation: 1 College of Chemistry and Chemical Engineering, China University of Petroleum, Qingdao 266555, China Corresponding author: Liu, F. (liufangfw@163.com) Source title: Shiyou Xuebao, Shiyou Jiagong/Acta Petrolei Sinica (Petroleum Processing Section) Abbreviated source title: Shiyou Xuebao Shiyou Jiagong Volume: 26 Issue: 3 Issue date: June 2010 Publication year: 2010 Pages: 456-461 Language: Chinese ISSN: 10018719 CODEN: SXSHEY Document type: Journal article (JA) Publisher: Science Press, 18,Shuangqing Street,Haidian, Beijing, 100085, China Abstract: With the decrease of water resources, the use of advanced treated refinery wastewater in recirculation cooling water system is an effective method to save water and to reduce the pollution of petroleum and petrochemical industry. However, the control of biofouling is the bottleneck in the application of this technology. So the effects of flow velocity and temperature on the components and characteristics of biofouling were investigated in a dynamic model unit of recirculation cooling water system. The results showed that the content of extracellular polymeric substance and the mechanical intensity of biofouling both reached its biggest values, but biofouling wet mass was low at the flow velocity of 1.0 m/s or at the temperature of 30°C. It is concluded that the operating conditions of 1.0 m/s and 30°C were the optimum conditions to control the biofouling in the recirculation cooling water system. Number of references: 12 Main heading: Water resources Controlled terms: Biofouling - Cooling - Cooling water - Flow velocity - Petroleum industry - Polymers - Ternary systems - Velocity - Wastewater - Wastewater treatment - Water cooling systems - Waterworks Uncontrolled terms: Cooling water temperature - Extra-cellular polymeric substances - Extracellular polymeric substance - Recirculation cooling water - Recirculations Classification code: 616.1 Heat Exchange Equipment and Components - 631 Fluid Flow - 641.2 Heat Transfer - 802.1 Chemical Plants and Equipment - 616 Heat Exchangers - 802.3 Chemical Operations - 815.1 Polymeric Materials - 931.1 Mechanics - 943.2 Mechanical Variables Measurements - 813 Coatings and Finishes - 531.2 Metallography - 446 Waterworks - 452.3 Industrial Wastes - 452.4 Industrial Wastes Treatment and Disposal - 461.2 Biological Materials and Tissue Engineering - 444 Water Resources - 472 Ocean Engineering - 512 Petroleum and Related Deposits - 513 Petroleum Refining - 531.1 Metallurgy - 511 Oil Field Equipment and Production Operations DOI: 10.3969/j.issn.1001-8719.2010.03.024 Database: Compendex Compilation and indexing terms, © 2010 Elsevier Inc. |

| 恭喜恭喜 |
| 8 | 1/1 | 返回列表 |
| 最具人氣熱帖推薦 [查看全部] | 作者 | 回/看 | 最后發(fā)表 | |
|---|---|---|---|---|