| 24小時(shí)熱門(mén)版塊排行榜 |
| 3 | 1/1 | 返回列表 |
| 查看: 988 | 回復(fù): 2 | ||
zbr405新蟲(chóng) (初入文壇)
|
[求助]
審稿意見(jiàn)求助 已有2人參與
|
|
各位蟲(chóng)友,我投的是Sensors and Actuators B, 17天就返回了審稿意見(jiàn),大家?guī)蛶兔,幫我理解一下審稿人的意思是什么,審稿意?jiàn)如下: Reviewers' comments: Reviewer #1: In this paper, the author prepared electrochemiluminescence aptasensing sensor based on ferrocene-graphene nanosheets for the detection of thrombin. However, the following issues need to be addressed before accept for publication: (1) The English of the manuscript needs improvement. (2) In the paper, the author said the ECL intensity of the Ru(bpy)32+ was quenched by Fc, but through the paper, the author did not prove the ECL intensity was actually quenched by Fc or graphene, as graphene also is a quencher. (3) In the experimental section, the author needs to briefly state how Fc-GNs were synthesized. (4) In fig. 6, what the author mean ECL intensity vs. time curves? Why not use the traditional ECL intensity vs. potential curves? (5) Statistical dada are missing in the figs with error bars, how many tests are repeated? Reviewer #2: This manuscript is a report containing innovation with new data for detection of thrombin. It is worthy to be published after some minor revisions. Some suggestions are listed as followings: 1. The voltage supplied to the photomuliplier for luminescence intensity determination needs to be confirmed. 2. A brief description about the mechanism of ECL through TPrA is better to be included in the manuscript. 3. A possible explanation for the optimal pH to give best activity is suggested. 4. The Nyquist plot was used to demonstrate a increase in charge transfer resistance after the formation of the insulating Ru-TBA layer. For a insulating layer, the electron resistance should also increase and showed an increase in the intercept with the Z' axis at high frequency. The manuscript is better to show this behavior. 5. Figure 5 shows that the ECL intensity change, <DELTA>IECL, was about 100 for Fc-GNs/Ru-TBA modified GCE. But, the ECL intensity change was about 300 without thrombin according calibration curve in Figure 6. Is there any explanation for this difference? |
捐助貴賓 (著名寫(xiě)手)

榮譽(yù)版主 (著名寫(xiě)手)
|
我嘗試?yán)斫庖幌掳桑?br />
審稿人1: 1、英語(yǔ)太爛了,得改。 2、你直接提出來(lái)一種解釋,卻沒(méi)有實(shí)驗(yàn)來(lái)證實(shí)。(這個(gè),如果實(shí)驗(yàn)實(shí)在做不出來(lái),可以說(shuō)由于實(shí)驗(yàn)條件限制什么的,然后找?guī)灼嚓P(guān)的文獻(xiàn)引證一下就行) 3、簡(jiǎn)要說(shuō)明制備方法。 4.為什么要用密度時(shí)間曲線? 5、這個(gè)應(yīng)該是說(shuō)你的統(tǒng)計(jì)曲線里,只有誤差棒,但是把原來(lái)的實(shí)驗(yàn)數(shù)據(jù)給隱藏了。還有,要額外點(diǎn)明統(tǒng)計(jì)了多少次實(shí)驗(yàn)的數(shù)據(jù)。 審稿2 : 1、好像是測(cè)定光強(qiáng)吧,應(yīng)該是補(bǔ)數(shù)據(jù)的意思 2、簡(jiǎn)述機(jī)制 3、解釋活性最佳ph值。 4、審稿人提出來(lái)一種什么現(xiàn)象或解釋之類的,我是外行,不懂,樓主自己理解吧。 5、Fig5和6不符,要求給個(gè)解釋。 感覺(jué)都不難回答,也沒(méi)有特別犀利的問(wèn)題。希望很大的 |
| 3 | 1/1 | 返回列表 |
| 最具人氣熱帖推薦 [查看全部] | 作者 | 回/看 | 最后發(fā)表 | |
|---|---|---|---|---|
|
[考研] 311求調(diào)劑一志愿合肥工業(yè)大學(xué) +4 | 秋二十二 2026-03-30 | 4/200 |
|
|---|---|---|---|---|
|
[考研] 材料與化工(0856)304求B區(qū)調(diào)劑 +4 | 邱gl 2026-03-30 | 8/400 |
|
|
[考研] 083000環(huán)境科學(xué)與工程調(diào)劑,總分281 +4 | 橙子(勝意) 2026-03-30 | 4/200 |
|
|
[考研] 抱歉 +4 | 田洪有 2026-03-30 | 4/200 |
|
|
[考研] 一志愿南昌大學(xué)324求調(diào)劑 +9 | hanamiko 2026-03-27 | 9/450 |
|
|
[考研]
|
鐘llll 2026-03-26 | 5/250 |
|
|
[考研] 322求調(diào)劑 +10 | 宋明欣 2026-03-27 | 10/500 |
|
|
[考研] 334分 一志愿武理 材料求調(diào)劑 +16 | 李李不服輸 2026-03-26 | 16/800 |
|
|
[考研] 293求調(diào)劑 +3 | 末未mm 2026-03-30 | 5/250 |
|
|
[考研] 324求調(diào)劑 +9 | hanamiko 2026-03-26 | 11/550 |
|
|
[考研] 070300一志愿211,312分求調(diào)劑院校 +4 | 小黃鴨寶 2026-03-30 | 4/200 |
|
|
[考研] 343求調(diào)劑085601 +3 | 要努力學(xué)習(xí)x 2026-03-29 | 3/150 |
|
|
[考研] 086000生物與醫(yī)藥調(diào)劑 +5 | Feisty。 2026-03-28 | 9/450 |
|
|
[考研] 343求調(diào)劑 +5 | 愛(ài)羈絆 2026-03-28 | 5/250 |
|
|
[考研] 一志愿華理,數(shù)一英一285求A區(qū)調(diào)劑 +8 | AZMK 2026-03-25 | 12/600 |
|
|
[考研] 求調(diào)劑 +6 | 蘆lty 2026-03-25 | 7/350 |
|
|
[考研] 081200-314 +3 | LILIQQ 2026-03-27 | 4/200 |
|
|
[考研] 292求調(diào)劑 +14 | 鵝鵝鵝額額額額?/a> 2026-03-25 | 15/750 |
|
|
[考博] 26申博 +3 | 加油沖。 2026-03-26 | 3/150 |
|
|
[考研] 316求調(diào)劑 +5 | Pigcasso 2026-03-24 | 5/250 |
|