| 5 | 1/1 | 返回列表 |
| 查看: 1884 | 回復(fù): 17 | ||||
| 當(dāng)前只顯示滿足指定條件的回帖,點擊這里查看本話題的所有回帖 | ||||
fzxiaofeixia鐵桿木蟲 (著名寫手)
|
[求助]
有幾條審稿意見不太理解,尋求 分析化學(xué) 相關(guān)高人指點,謝謝 已有2人參與
|
|||
|
1.Calibration Curves: a) The concentration values of the calibration solutions, or alternatively, the calibration scedasticity must be reported. b) It doesn't seem that replicates of the calibration solutions have been produced and injected. In fact, table 3 does not report the measurement error, which is usually calculated by the standard deviation of the calibration curve. This point is particularly important because the analysis of trace measurement error may be greater than the measure itself.對這條兩條意見不明白,請高人指點! 2.The authors reported that the intra-day and inter-day precisions were 7.39 and 9.77 % respectively. What are the respectively SD? Specify the abbreviation of RSD... 審稿人想表達的確切意見是? 3.如果發(fā)現(xiàn)的審稿人的意見明顯是錯誤的,怎么回復(fù)?最好有英文模板 ![]() |
鐵桿木蟲 (著名寫手)
鐵桿木蟲 (著名寫手)
專家顧問 (著名寫手)
![]() |
專家經(jīng)驗: +218 |
|
我搞凝聚態(tài)物理的,可能理解得不對,但愿意說出來,供你參考。 1.Calibration Curves: a) The concentration values of the calibration solutions, or alternatively, the calibration scedasticity must be reported. b) It doesn't seem that replicates of the calibration solutions have been produced and injected. In fact, table 3 does not report the measurement error, which is usually calculated by the standard deviation of the calibration curve. This point is particularly important because the analysis of trace measurement error may be greater than the measure itself.對這條兩條意見不明白,請高人指點! 第一點是說你應(yīng)該報道所有定標(biāo)液的濃度值,或者它們的統(tǒng)計分布(即平均值和標(biāo)準(zhǔn)差)。 第二點是審稿人猜測你實際上只用了一個樣品,因為表3中沒有報道測量誤差(即標(biāo)準(zhǔn)差)。 我的建議,如果你只測了一個樣品,要么繼續(xù)補樣品,要么回答審稿人你只測了一個以及為什么認(rèn)為一個就足夠了。如果你測了多個樣品,那么也告訴審稿人你測了多個,但沒有報道定標(biāo)液濃度的統(tǒng)計分布以及結(jié)果的誤差。 2.The authors reported that the intra-day and inter-day precisions were 7.39 and 9.77 % respectively. What are the respectively SD? Specify the abbreviation of RSD... 審稿人想表達的確切意見是讓你除了報道兩種情況的precision之外還要報道它們的SD(我猜是standard deviation?)。另外,請告訴讀者RSD代表什么(我估計是Relative standard deviation)!咀ⅰ浚何业睦斫馐牵耗銏蟮赖膒recision其實就是RSD,是個百分比(相對值),但審稿人想知道絕對標(biāo)準(zhǔn)差是多少。 3.如果發(fā)現(xiàn)的審稿人的意見明顯是錯誤的,怎么回復(fù)?最好有英文模板 反駁就是了。例如:We thank the Referee for pointing out this, but we do not agree with her/him regarding this point. ... (Then you can "teach" the Referee something here.) |
專家顧問 (著名寫手)
![]() |
專家經(jīng)驗: +218 |
| 最具人氣熱帖推薦 [查看全部] | 作者 | 回/看 | 最后發(fā)表 | |
|---|---|---|---|---|
|
[考研] 298-一志愿中國農(nóng)業(yè)大學(xué)-求調(diào)劑 +11 | 手機用戶 2026-03-17 | 12/600 |
|
|---|---|---|---|---|
|
[考研] 接收2026碩士調(diào)劑(學(xué)碩+專碩) +4 | allen-yin 2026-03-23 | 6/300 |
|
|
[考研] 招08考數(shù)學(xué) +6 | laoshidan 2026-03-20 | 14/700 |
|
|
[考研] 280分求調(diào)劑 一志愿085802 +4 | PUMPT 2026-03-22 | 7/350 |
|
|
[考研] 尋找調(diào)劑 +4 | 倔強芒? 2026-03-21 | 4/200 |
|
|
[考研] 一志愿中南化學(xué)(0703)總分337求調(diào)劑 +9 | niko- 2026-03-19 | 10/500 |
|
|
[考研] 324求調(diào)劑 +6 | lucky呀呀呀鴨 2026-03-20 | 6/300 |
|
|
[考研] 085600材料與化工306 +4 | z1z2z3879 2026-03-21 | 4/200 |
|
|
[考研] 初試 317 +7 | 半拉月丙 2026-03-20 | 7/350 |
|
|
[考研] 考研調(diào)劑 +3 | 呼呼?~+123456 2026-03-21 | 3/150 |
|
|
[考研] 材料與化工(0856)304求B區(qū)調(diào)劑 +3 | 邱gl 2026-03-20 | 7/350 |
|
|
[考研] 【考研調(diào)劑】化學(xué)專業(yè) 281分,一志愿四川大學(xué),誠心求調(diào)劑 +11 | 吃吃吃才有意義 2026-03-19 | 11/550 |
|
|
[考研] 初始318分求調(diào)劑(有工作經(jīng)驗) +3 | 1911236844 2026-03-17 | 3/150 |
|
|
[考研] 一志愿武理材料305分求調(diào)劑 +6 | 想上岸的鯉魚 2026-03-18 | 7/350 |
|
|
[考研] 一志愿 南京航空航天大學(xué)大學(xué) ,080500材料科學(xué)與工程學(xué)碩 +5 | @taotao 2026-03-20 | 5/250 |
|
|
[考研] 085410人工智能專碩317求調(diào)劑(0854都可以) +4 | xbxudjdn 2026-03-18 | 4/200 |
|
|
[考研] 材料學(xué)碩318求調(diào)劑 +5 | February_Feb 2026-03-19 | 5/250 |
|
|
[考研] 085600材料與化工求調(diào)劑 +6 | 緒幸與子 2026-03-17 | 6/300 |
|
|
[考研] 收復(fù)試調(diào)劑生 +4 | 雨后秋荷 2026-03-18 | 4/200 |
|
|
[考研] 考研求調(diào)劑 +3 | 橘頌. 2026-03-17 | 4/200 |
|